Tian Yongquan, Ma Chongfang, Lei Daoheng. Two-phase Two-component Jet Impingement Heat Transfer on A Small Vertical Heater[J]. Journal of Beijing University of Technology, 1989, 15(3): 27-32.
    Citation: Tian Yongquan, Ma Chongfang, Lei Daoheng. Two-phase Two-component Jet Impingement Heat Transfer on A Small Vertical Heater[J]. Journal of Beijing University of Technology, 1989, 15(3): 27-32.

    Two-phase Two-component Jet Impingement Heat Transfer on A Small Vertical Heater

    • Experimental study was performed to measure the local heat transfer coefficient of a small vertical heater impinged with a single jet of N2 gaswater mixture. Very high heat transfer coefficient was recorded at high jet velocity. It was found that heat flux as high as 2.8×108 W/m2 was disspated at room temperature from a heated surface, maintaining low temperature only at 58℃. A low heat flux so called negtivc temperature difference was measured. The effects of jet velocity and nozzle-to-plate spacing were investigated experimentally. This cooling method is proposed to be used in microelectronic devices.