QI Lu, WANG Hong-chen, ZHENG Xiang, LIU Guo-hua, LIANG Heng, LI Gui-bai. Effect of Filtration Modes on the Immersed UF Membrane Effluent Quality and Fouling[J]. Journal of Beijing University of Technology, 2013, 39(2): 304-308.
    Citation: QI Lu, WANG Hong-chen, ZHENG Xiang, LIU Guo-hua, LIANG Heng, LI Gui-bai. Effect of Filtration Modes on the Immersed UF Membrane Effluent Quality and Fouling[J]. Journal of Beijing University of Technology, 2013, 39(2): 304-308.

    Effect of Filtration Modes on the Immersed UF Membrane Effluent Quality and Fouling

    • The operating condition is an important factor affecting the membrane filtration performance.Effects of filtration modes including constant pressure and constant flux on UF effluent quality and membrane fouling were investigated.Results of the pilot-scale experiment show that the removal of particulate and organic matters by UF has little difference in constant pressure and constant flux conditions.In the long period of operation,more seriously irreversible fouling can be caused by filtration in constant pressure than in constant flux condition.Membrane filtration operation can remain stable in very long period in constant flux condition by selecting a reasonable flux and cleaning method.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return