Tang Fujiang, Ma Chongfang, Gan Yongping, et al, . Experimental Study of Nucleate Boiling Enhanced by Screw-metal-wire-wrapped Tube[J]. Journal of Beijing University of Technology, 1989, 15(3): 14-19.
    Citation: Tang Fujiang, Ma Chongfang, Gan Yongping, et al, . Experimental Study of Nucleate Boiling Enhanced by Screw-metal-wire-wrapped Tube[J]. Journal of Beijing University of Technology, 1989, 15(3): 14-19.

    Experimental Study of Nucleate Boiling Enhanced by Screw-metal-wire-wrapped Tube

    • The experiments demonstrate that the horizontal plain tube wrapped with screw metal wire remarkably enhaaces heat transfer in nucleate pool boiling of R-113, R-11 and ethanal, has no "Temperature Overshoot" in Freon pool boiling and outperforms the GAWA-T tube. On the basis of dimensional analysis a correlation has been obtained. Compared with the experimental data, the correlation has a mean absolute error of 25%.