Abstract
The preparation, constitution and application in cyclohexane dehydrogenation of membrane reactor with molecular sieve silicon membranes are studied. The experiment results show that the conversion of cyclohexane dehydrogenation depends on space time. At space time t=15s the conversion is 10%higher than the equilibrium conversion.
-
-