一体式PAC-UF工艺处理水厂待滤水的中试研究
Pilot-scale Study on Hybrid PAC-UF Process for Settled Water Treatment
-
摘要: 通过中试,研究一体式PAC-UF工艺取代传统砂滤池工艺的适用性和经济性,并将其与单独超滤和水厂砂滤池比较.结果表明,PAC-UF工艺平均出水浊度为(0.041±0.010)NTU,粒径>2μm的颗粒数平均为(13±8)/mL,可保证出水良好的生物安全性.在PAC投加20 mg/L情况下,PAC-UF工艺对CODMn的去除率为(21.0±9.9)%,对不含亚硝酸盐部分CODMn的去除率为(33.7±11.1)%,对UV254的去除率为(51.0±10.7)%,PAC-UF工艺对浊度和有机物的去除效果明显优于传统砂滤.但PAC-UF工艺对NH4+-N去除效果不佳.在实验工况条件下,工艺能稳定运行,可以维持运行3个月左右化学清洗1次.PAC-UF工艺适用于高有机污染、低NH4+-N的原水水质,它可以有效地提高水厂出水的生物安全性和化学安全性.Abstract: Pilot-scale study was performed to investigate the hybrid PAC-UF process for settled water treatment in terms of validity and economic efficiency of it as a substitute of the conventional sand filter.The performance of the hybrid PAC-UF process was also compared with that of the conventional sand filter in the full-scale drinking water treatment plant and UF.Resultsshowed that,the hybrid PAC-UF process could ensure the biological-safety with(0.041±0.010) NTU and(13±8)/mL for the effluent of turbidity and particle number(particle size >2 μm).The process reduced influent CODMn and UV254 by(21.0±9.9)% and(51.0±10.7)%,respectively.The process had a better performance for organic matter and turbidity removal compared with the conventional process,but it couldn't remove NH4+-N effectively.The process could running stably under the experimental condition.The hybrid PAC-UF process was suitable for the raw water with high concentration organic matter and low concentration NH4+-N.It could ensure the chemical-safety and biological-safety of effluent.